Items |
9000 THA Baseline® 9000 THA Total Hydrocarbons Analyzer |
9000 MNME Baseline® 9000 MNME Methane/Non Methane Analyzer |
9000 MNME 120 Baseline® 9000 MNME 120 Methane/Non Methane Analyzer |
9000 TCA Baseline® 9000 TCA Hydrocarbons and CO/CO2 Analyzer |
9000 H Baseline® 9000 H-THA Heated Total Hydrocarbons Analyzer |
|||||
Description | N/A The 9000 total Hydrocarbon analyzer is a versatile instrument for use in numerous applications ranging from parts-per billion level detection for trace analysis in ultra pure gases to % level for process optimization or LEL monitoring. | N/A The 9000 Methane/Non-Methane analyzer uses a flame ionization detector (FID) in conjunction with an oxidation catalyst that oxidizes all hydrocarbons except methane to produce a methane measurement which is then subtracted from the total concentration to determine the non-methane hydrocarbon reading. | N/A The 9000 Methane/Non-Methane analyzer uses a flame ionization detector (FID) in conjunction with an oxidation catalyst that oxidizes all hydrocarbons except methane to produce a methane measurement which is then subtracted from the total concentration to determine the non-methane hydrocarbon reading. | N/A The 9000 Total Carbon analyzer utilizes a flame ionization detector (FID) in conjunction with a catalytic methanizer that converts the CO and CO2 to methane (CH4) and leaves the hydrocarbons unchanged for a total carbon measurement which is then subtracted from the total carbon concentration to determine the combined CO/CO2 reading. | N/A The 9000 Heated analyzer functions likeThe 9000 THA but is configured for single point analysis (with or without a sample pump) of samples heated up to 376 °F (191 °C) for pre-filtered (< 10 microns) noncondensing samples. | |||||
Brands | N/A AMETEK® MOCON® | |||||||||
Accurate Detection |
N/A
|
N/A
|
N/A
|
N/A
|
N/A | |||||
Detector | N/A Flame Ionization Detector (FID) | N/A Flame Ionization Detector (FID) with Oxidizer | N/A Flame Ionization Detector (FID) with Oxidizer | N/A Flame Ionization Detector (FID) | N/A Flame Ionization Detector (FID) with Oxidizer | |||||
Ranges (CH4) |
N/A
User definable based upon calibration:
|
N/A
User definable based upon calibration:
|
N/A
User definable based upon calibration:
|
N/A
User definable based upon calibration: |
N/A
User definable based upon calibration:
|
|||||
Accuracy | N/A +1% full-scale response. | |||||||||
Drift, Zero | N/A +0.025% full-scale over 24 hours. | N/A +0.01% full-scale, 24 hours. | N/A +0.01% full-scale, 24 hours. | N/A +0.01% full-scale, 24 hours. | N/A +0.025% full-scale, 24 hours. | |||||
Drift, Span | N/A +1% full-scale, 24 hours. | |||||||||
Response Time | N/A T90 < 5 s | N/A T90 < 30 s | N/A T90 < 30 s | N/A T90 < 30 s | N/A T90 < 5 s | |||||
Sampling | N/A Internal single or multi-point, (pump optional) | N/A Internal single or multi-point, (pump optional) | N/A Internal single or multi-point, (pump optional) | N/A Internal single point (pump optional) | N/A Internal single point (pump optional) | |||||
Alarms | N/A Multilevel concentration and fault alarms, audible and visual. | |||||||||
Calibration | N/A Manual Calibration Programmable Automatic | |||||||||
Support Gas Requirement1 |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
Display Width | N/A 3.4 in8.64 cm | |||||||||
Display Length | N/A 4.5 in11.43 cm | |||||||||
Display Type | N/A Graphical Liquid Crystal Display (LCD) | |||||||||
Outputs |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
Operating Temperature | N/A 32 to 104 ºF0 to 40 ºC | |||||||||
Non-Condensing Operating Humidity | N/A 0 to 95 % | |||||||||
Configuration | N/A Benchtop or 19" (48.3 cm) Rack-Mount, 3U | |||||||||
Prevenitive Maintenance Kit | N/A Includes all parts potentially needed on-hand | |||||||||
Gas Generators |
N/A
|
|||||||||
Software | N/A 9000 Keeper provided for method switching via PC | |||||||||
Service and Support Options | N/A Start-up and training, 1 day onsite | |||||||||
Height | N/A 5.25 in13.02 cm | |||||||||
Width | N/A 19 in48.26 cm | |||||||||
Depth | N/A 16.25 in41.28 cm | |||||||||
Weight | N/A <20 lb9.07 kg | |||||||||
Alternating Current (AC) Voltage | N/A 100 to 240 V | |||||||||
Frequency | N/A 50 Hz60 Hz | |||||||||
Current | N/A 1 A | |||||||||
Applications |
N/A
|
N/A
|
N/A
|
N/A
Hydrocarbon & CO/CO2 Impurities in Ultra-Pure Gasses
|
N/A
|
|||||
Features |
N/A
|
|||||||||
Additional Information | N/A All instrument parameters are reported clearly and continually refreshed on a large, graphical LCD display. Using analog, digital, and logic output communication capabilities, analytical information from the analyzer can be acquired using an external PC and a simple communications program such as Windows® HyperTerminal or the analyzer can output binary or ASCII formats directly to a data acquisition system or PLC. Every Baseline® 9000 analyzer includes MOCON’s free PC utility 9000 Keeper used for storing and uploading multiple methods, as well as sending configuration settings, directly to the analyzer. | |||||||||
|