Brands |
N/A AMETEK® MOCON® |
Detector |
N/A
Selected by application: Flame Ionization (FID) Photoionization (PID) High-Sensitivity Photoionization (HS-PID) Thermal Conductivity (TCD) |
Sampling |
N/A
Single or multipoint (4 or 8 pt) internal sampler Internal pump optional Optional external sampler (BASELINE® 9150) for >8 sample points |
Columns |
N/A Packed, micro-packed, or capillary specific to application |
Connections |
N/A 1/4" or 1/8" OD tube compression fitting or 1/8" legris |
Alarms |
N/A Multilevel concentration and fault alarms, audible and visual |
Calibration |
N/A Automatic or manual using a dedicated standard |
Calibration Methods |
N/A Gas cylinder, permeation calibrator, or response factors |
Display |
N/A 7" Color LCD Touchscreen |
Outputs/Inputs, Standard |
N/A 2 USB Ports for LAN/Ethernet RS-232 |
Outputs/Inputs, Optional |
N/A
I/O Board: 6 digital inputs, 5 relays as contact closures, 1 analog Analog Board: 4 or 8 configurable as 4-20mA or 0-20mA Relay Board: 8 or 16 programmable contact closures |
Operating Temperature |
N/A 32 to 104 ºF0 to 40 ºC |
Non-Condensing Operating Humidity |
N/A 0 to 95 % |
Configuration |
N/A Benchtop or 19" (48.3 cm) Rack-Mount, 3U |
Height |
N/A 5.12 in13 cm |
Width |
N/A 19 in48.26 cm |
Depth |
N/A 22.4 in56.9 cm |
Weight |
N/A <30 lb13.64 kg |
Alternating Current (AC) Voltage |
N/A 100 to 230 V |
Frequency |
N/A 50 Hz60 Hz |
Current |
N/A 2 A |
Applications |
N/A
Environmental Monitoring
|
Features and Benefits |
N/A
Automated Control Features
|
Additional Features |
N/A
Multiple GC Analyses or GC & Total Gas
|
Accessories |
N/A
Preventive Maintenance Kitul
|
Additional Information |
N/A
AMETEK® MOCON® will select the best detectors for your application commonly utilizing Photoionization (PID), High-sensitivity Photoionization (HS-PID), Flame Ionization (FID), or Thermal Conductivity (TCD). Analytical arrangements typically involve a single valve, two column configuration, but may vary depending upon the application and if a dual-GC or GC/THA is being utilized. The BASELINE® 9200 touchscreen LCD display and internal system software keep configuration and operation simple and the automatic calibration feature is ideal for unattended operation. The compact size and design make this unit suitable for field applications, allowing for either rack mount configuration or bench top use. A full suite of user configurable data collection, storage and outputs allow the 9200 to speak your language, your way. Users can configure up to 1 year of on-board storage of chromatograms, ASCII results via RS-232 or LAN, contact closure relays and 4-20 mA analog outputs, all independent of one another. |