Brands |
N/A AMETEK® Dansensor® MOCON® |
Mixer Configurations |
N/A 2-gas or 3-gas models available, with LCD display or as "Black-Box" without display |
Connections |
N/A 2 x RS232C| LAN 10/100 Mbit (Modbus TCP)| USB| 24 VDC Logic for Start/Stop and Alarm |
Alternating Current (AC) Voltage1 | N/A 103 to 132 V207 to 264 V |
Frequency |
N/A 47 to 63 Hz |
Note for Power Supply |
N/A 24 VDC models available (excl. MAP Mix Provectus Argon) |
Height |
N/A 192 mm |
Width |
N/A 230 mm |
Depth |
N/A 375 mm |
Weight |
N/A 12.0 to 14.0 kg |
Compliances |
N/A European Conformity (CE) |
Gas Media |
N/A Any mix of dry O2, CO2, N2, air or Ar (optional) (0°C to +50°C gas temperature) |
Gas Inlet Pressure |
N/A 2 to 10 bar |
Pressure Drop |
N/A Example: 1 bar at 10 bar input pressure |
Gas flow per Gas String |
N/A 6 to 500 L/min |
Output Gas Flow |
N/A Total output flow up to: 1000 L/min (2-gas) and 1500 L/min (3-gas) depending on mixture setting. |
Mixer Setting Range |
N/A 0 %2 to 100 % |
Mixer Accuracy |
N/A ± 2% absolute in flow ranges above 50 L/min total output flow. Argon: ± 2% absolute at argon flow > 50 bar |
Flow Measuring |
N/A Total and daily consumption. |
Operating Modes |
N/A Buffer or flow configuration, selectable in software and by installation |
Protection Kit |
N/A Ingress Protection (IP45) National Electrical Manufacturers Association (NEMA 3S) |
Bracket, Assembly |
N/A Can be combined with MAP Check 3 Vacuum and MAP Check 3: 2 brackets, 8 screws. |
Flow Range for Typical Mix1 for 2 Gases at (N2 80% + CO2 20%) |
N/A 30 to 625 L/min |
Flow Range for Typical Mix1 for 3 Gases at (N2 70% + CO220% +O210%) |
N/A 60 to 714 L/min |
Flow Range for Typical Mix2 for 2 Gases at (N2 60% + CO2 40%) |
N/A 15 to 833 L/min |
Flow Range for Typical Mix2 for 3 Gases at (N2 70% + CO228% + O22%) |
N/A 300 to 714 L/min |
Flow Range for Worst Case Mix for 2 Gases at (N2 98% + CO2 2%) |
N/A 300 to 509 L/min |
Flow Range for Worst Case Mix for 3 Gases at (N2 88% + CO210% + O22%) |
N/A 300 to 568 L/min |
Flow Range for Best Case Mix for 2 Gases at (N2 50% + CO2 50%) |
N/A 12 to 1000 L/min |
Flow Range for Best Case Mix for 3 Gases at (N2 34% + CO233% + O233%) |
N/A 18 to 1470 L/min |
Additional Information |
N/A Despite its compact size, the Dansensor® MAP Mix Provectus delivers an outstanding flow of up to 1500 liters per minute. If you require a higher flow rate, you can bridge up to three mixers and triple the capacity. |
Benefits |
N/A
|
Features |
N/A
|
How Does it Work? |
N/A
|