Items |
2/22 H OX-TRAN® Series 2/22 H Oxygen Permeation Analyzer |
2/22 L OX-TRAN® Series 2/22 L Oxygen Permeation Analyzer |
2/22 10X OX-TRAN® Series 2/22 10X Oxygen Permeation Analyzer |
|||
Description |
N/A
Entry-level oxygen and water vapor transmission testing for barrier films and packages. Practical Permeation Transmission Rate Measurement The OX-TRAN® 2/22 1-cell and the Aquatran® 3/34 1-cell are low-cost units designed for testing Oxygen Transmission Rates (OTR) or Water Vapor Transmission Rates (WVTR) from low to high barriers. They are designed for both first-time users and advanced operators, providing accurate and repeatable test results within a wide detection range. Each model is designed for high-performance film testing, with the capability for whole-package testing. They feature one test cell with a changeable horizontal test cartridge that allow testing of a wide variety of sample sizes and types. |
N/A
High Performance OTR Testing for Barrier Films & Packages High Performance Oxygen Permeation Analyzer The OX-TRAN® 2/22 series of high-performance analyzers provide the highest accuracy and lowest level of Oxygen Transmission Rate (OTR) detection on the market. With three different models they can test both films and packages from low- to ultra-high level barriers. The analyzers are easy-to-use and offer the shortest test times available with the AMETEK® mocon® patented Coulox sensor. They feature two independent cells with changeable horizontal test cartridges that allow a wide variety of sample sizes and types to tested. |
N/A
High Performance OTR Testing for Barrier Films & Packages High Performance Oxygen Permeation Analyzer The OX-TRAN® 2/22 series of high-performance analyzers provide the highest accuracy and lowest level of Oxygen Transmission Rate (OTR) detection on the market. With three different models they can test both films and packages from low- to ultra-high level barriers. The analyzers are easy-to-use and offer the shortest test times available with the AMETEK® mocon® patented Coulox sensor. They feature two independent cells with changeable horizontal test cartridges that allow a wide variety of sample sizes and types to tested. |
|||
Brands | N/A AMETEK® MOCON® OX-TRAN® | |||||
Barrier Level | N/A Low to High | N/A Low to High | N/A Low to Ultra-High | |||
Detection Range | N/A 0.05 to 200 cm³/(m²·day) | N/A 0.005 to 200 cm³/(m²·day) | N/A 0.0005 to 200 cm³/(m²·day) | |||
Depth | N/A 23 in58.0 cm | |||||
Width | N/A 12 in30.4 cm | |||||
Height | N/A 15.5 in39.4 cm | |||||
Weight | N/A 95 lb43.1 kg | |||||
Test Temperature Range | N/A | N/A 10 to 40 ºC | N/A 10 to 40 ºC | |||
Test Temperature Range Tolerance (±) | N/A | N/A 0.2 ºC | N/A 0.2 ºC | |||
Controlled Relative Humidity (RH) Testing Range | N/A 0 %30 to 90 % | N/A 0 %5 to 90 % | N/A 0 %5 to 90 % | |||
Controlled Relative Humidity (RH) Testing Range Tolerance (±) | N/A 3 % | |||||
Maximum Film Thickness | N/A | N/A Up to 120 mil | N/A Up to 120 mil | |||
Carrier Gas | N/A Nitrogen/Hydrogen Mix (98%/2%) | |||||
Test Gas | N/A 100% Oxygen (99.9% pure) | |||||
Test Range for Normal Model (50 cm²) | N/A 0.05 to 200 cm³/(m²·day)0.003 to 12.9 cm³/(100 in²·day)0.00025 to 1.0 cm³/(pkg·day) | N/A 0.005 to 200 cm³/(m²·day)0.0003 to 12.9 cm³/(100 in²·day)0.000025 to 1.0 cm³/(pkg·day) | N/A 0.0005 to 200 cm³/(m²·day)0.00003 to 12.9 cm³/(100 in²·day)0.0000025 to 1.0 cm³/(pkg·day) | |||
Test Range for Reduced Area Cartridge (5.64 cm²) | N/A | N/A 0.044 to 1770 cm³/(m²·day)0.0027 to 114.0 cm³/(100 in²·day) | N/A 0.0044 to 1770 cm³/(m²·day)0.00027 to 114.0 cm³/(100 in²·day) | |||
Resolution at 50 Square Centimeter (cm²) | N/A | N/A 0.0001 cm³/(m²·day) | N/A 0.0001 cm³/(m²·day) | |||
Repeatability1 | N/A | N/A 0.002 cm³/(m²·day)1 % | N/A 0.0005 cm³/(m²·day)1 % | |||
Temperature Control Range | N/A 20 to 40 ºC | N/A | N/A | |||
Temperature Control Range Tolerance (±) | N/A 0.2 ºC | N/A | N/A | |||
Film Thickness | N/A Up to 120 mil3 mm | N/A | N/A | |||
Test Range for Masked Model (5.0 cm²) | N/A 0.5 to 2000 cm³/(m²·day)0.03 to 129 cm³/(100 in²·day) | N/A | N/A | |||
Resolution for Normal Model (50 cm²) | N/A 0.0001 cm³/(m²·day) | N/A | N/A | |||
Repeatability for Normal Model (50 cm²) | N/A 0.02 cm³/(m²·day) or 1% | N/A | N/A | |||
Industry Standards | N/A American Society for Testing and Materials (ASTM) D3985 American Society for Testing and Materials (ASTM) F 2622 American Society for Testing and Materials (ASTM) F1307 American Society for Testing and Materials (ASTM) F1927 German Institute for Standardization (DIN) 53380-3 International Organization for Standardization (ISO) CD 15105-2 Japanese Industrial Standards (JIS) K-7126-B National Standard (Recommended) (GB/T) 19789-2005 | N/A American Society for Testing and Materials (ASTM) D3985 American Society for Testing and Materials (ASTM) F1307 American Society for Testing and Materials (ASTM) F1927 American Society for Testing and Materials (ASTM)F2622 German Institute for Standardization (DIN) 53380-3 International Organization for Standardization (ISO) CD 15105-2 Japanese Industrial Standards (JIS) K-7126-B National Standard (Recommended) (GB/T) 19789-2005 National Standard (Recommended) (GB/T) 31354-2014 | N/A American Society for Testing and Materials (ASTM) D3985 American Society for Testing and Materials (ASTM) F1307 American Society for Testing and Materials (ASTM) F1927 American Society for Testing and Materials (ASTM)F2622 German Institute for Standardization (DIN) 53380-3 International Organization for Standardization (ISO) CD 15105-2 Japanese Industrial Standards (JIS) K-7126-B National Standard (Recommended) (GB/T) 19789-2005 National Standard (Recommended) (GB/T) 31354-2014 | |||
Conformance Standards | N/A Canadian Standards Association (CSA) Safety Compliance European Conformity (CE) Underwriters Laboratories (UL) | |||||
Connectivity |
N/A
|
N/A 2 Universal Serial Bus (USB) Ports Optional PERM-NET Lite™ for Remote Monitoring Port | N/A 2 Universal Serial Bus (USB) Ports Optional PERM-NET Lite™ for Remote Monitoring Port | |||
Accessories |
N/A
|
N/A
|
N/A
|
|||
Coulox® Sensor | N/A | N/A The OX-TRAN® 2/22 Series use AMETEK® mocon®'s patented Coulox sensor which is an absolute (intrinsic) coulometric sensor requiring no calibration and is the basis for the ASTM standard D3985. It is the only instrument family proven to meet ASTM's precision and bias requirement through independent and 3rd party testing. | N/A The OX-TRAN® 2/22 Series use AMETEK® mocon®'s patented Coulox sensor which is an absolute (intrinsic) coulometric sensor requiring no calibration and is the basis for the ASTM standard D3985. It is the only instrument family proven to meet ASTM's precision and bias requirement through independent and 3rd party testing. | |||
Extensive Testing Capabilities and Applications | N/A | N/A The accuracy and wide testing capability of the 2/22 Series make it an ideal OTR instrument for both research and development or production support laboratories. It has the capability to test from mono-layer to multi-layer films, coated films to coated paper board, and specialty applications such as gels or lotions. With the optional adapter cartridge it can also test complete or partial packages, flexible or rigid containers, bottles/closures, and seals in the form of O-rings or gaskets. The interchangeable cartridges also work with other Next Generation AMETEK® mocon® permeation analyzers. These purpose-built cartridges increase accuracy, extend the range, or make it possible to test unique or difficult samples. | N/A The accuracy and wide testing capability of the 2/22 Series make it an ideal OTR instrument for both research and development or production support laboratories. It has the capability to test from mono-layer to multi-layer films, coated films to coated paper board, and specialty applications such as gels or lotions. With the optional adapter cartridge it can also test complete or partial packages, flexible or rigid containers, bottles/closures, and seals in the form of O-rings or gaskets. The interchangeable cartridges also work with other Next Generation AMETEK® mocon® permeation analyzers. These purpose-built cartridges increase accuracy, extend the range, or make it possible to test unique or difficult samples. | |||
Removable Cartridges | N/A |
N/A
|
N/A
|
|||
TruSeal® | N/A |
N/A
|
N/A
|
|||
Control Features | N/A |
N/A
|
N/A
|
|||
Advanced Control System | N/A | N/A The user friendly WinPerm 2 control system features fully automated testing including temperature, gas flow and RH control. Final test reports are automatically saved and can be set to automatically print and export to permanent storage directories. The analyzer is compatible with PermWare™, your complete permeation laboratory data management system. The test mode options make testing known or unknown samples easy and repeatable. A single button push initiates a fully automated test following pre-set stored parameters, reducing operator variability. The intuitive color touch screen is easy to learn and use while the automated testing provides consistent results and fewer potential errors. | N/A The user friendly WinPerm 2 control system features fully automated testing including temperature, gas flow and RH control. Final test reports are automatically saved and can be set to automatically print and export to permanent storage directories. The analyzer is compatible with PermWare™, your complete permeation laboratory data management system. The test mode options make testing known or unknown samples easy and repeatable. A single button push initiates a fully automated test following pre-set stored parameters, reducing operator variability. The intuitive color touch screen is easy to learn and use while the automated testing provides consistent results and fewer potential errors. | |||
Accuracy in Oxygen Permeation Testing | N/A | N/A The OX-TRAN® 2/22 series analyzers feature our exclusive test cell drawer design with two horizontal removable easy-to-load cartridges improve test repeatability. A single button opens and closes the drawers, and the cartridge is automatically clamped in place with consistent and even force on any sample thickness. This approach provides greater test repeatability than manual or cam clamping methods. All test cartridges incorporate AMETEK® mocon®'s exclusive TruSeal® design that utilizes two seals and flushes gas between them to prevent ambient ingress into the test area. This reduces background levels, improves repeatability, and reduces the need to run individual zero. | N/A The OX-TRAN® 2/22 series analyzers feature our exclusive test cell drawer design with two horizontal removable easy-to-load cartridges improve test repeatability. A single button opens and closes the drawers, and the cartridge is automatically clamped in place with consistent and even force on any sample thickness. This approach provides greater test repeatability than manual or cam clamping methods. All test cartridges incorporate AMETEK® mocon®'s exclusive TruSeal® design that utilizes two seals and flushes gas between them to prevent ambient ingress into the test area. This reduces background levels, improves repeatability, and reduces the need to run individual zero. | |||
Touchscreen Interface | N/A |
N/A
|
N/A
|
|||
Coulox® Sensor (Trusted Result) | N/A |
N/A
|
N/A
|
|||
Warranty |
N/A
|
N/A
|
N/A
|
|||
Features |
N/A
Interchangeable Cartridges for Testing Versatility These instruments feature our exclusive test cell drawer design with one horizontal removable easy-to-load test cartridge that improves test repeatability. One button opens and closes the drawers, and the cartridge is automatically clamped in place with consistent force on any sample thickness. This provides greater test repeatability than manual or cam-clamping methods. With the cartridge removed, it is easy to clean and consistently load samples on the bench-top, reducing operator variability. The interchangeable cartridges also work with other MOCON® permeation analyzers. These purpose-built cartridges increase accuracy, extend the range, or make it possible to test unique or difficult samples. All test cartridges incorporate our proprietary TruSeal® design, which uses two seals and flushes gas between them to prevent ambient ingress into the test area. This reduces background levels, improves repeatability, and reduces the need to run individual zero. Testing Capabilities and Applications These 1-cell models are designed to be effective yet simple-to-use instruments for a wide range of applications where low throughput is acceptable. The testing capability make them an ideal OTR or WVTR instrument to test single samples from mono-layer to multi-layer films, coated films and coated paper board. Whether it is research and development at a university or as a QC instrument to support production operations, the 1-cell modules provide reliable data to support your permeation testing needs. |
N/A | N/A | |||
Additional Information |
N/A
Simple Operation Precision Measurement with Our Accurate Sensors The OX-TRAN 2/22 uses our patented COULOX® sensor, an absolute (intrinsic) coulometric sensor requiring no calibration and the basis for ASTM standard D3985. This sensor is proven to meet ASTM's precision and bias requirement through independent and third-party testing. User-friendly Automated Testing The WinPerm™ 2.5 control system features fully automated testing, including temperature, gas flow and RH control. Final test reports are automatically saved and can be set to automatically print and export to permanent storage directories. One push of a button initiates a fully automated test following pre-set stored parameters, reducing operator variability. The intuitive color touchscreen reduces the learning curve, while the automated testing provides consistent results and fewer errors. The analyzer is compatible with PermWare®, a complete permeation laboratory data management system. |
N/A | N/A | |||
|