OX-TRAN® 1/50 OX-TRAN® 1/50 Series Oxygen and Water Vapor Permeation Analyzer |
Permatran-W® 1/50 Permatran-W® 1/50 Series Oxygen and Water Vapor Permeation Analyzer |
||
Description |
N/A
Basic OTR Testing for Barrier Films Practical Permeation Transmission Rate Measurement The OX-TRAN® model 1/50 is low-cost units designed for testing Oxygen Transmission Rate (OTR) on films from low to high barriers. They are designed for both first-time users and the advanced operator, providing accurate and repeatable test results within a wide detection range. |
N/A
Basic WVTR Testing for Barrier Films Practical Permeation Transmission Rate Measurement The Permatran-W® 1/50 G are low-cost units designed for testing Water Vapor Transmission Rates (WVTR) respectively on films from low to high barriers. They are designed for both first-time users and the advanced operator, providing accurate and repeatable test results within a wide detection range. |
||
Brands | N/A AMETEK® MOCON® OX-TRAN® | N/A AMETEK® MOCON® PERMATRAN-W® | ||
Depth | N/A 18 in45.7 mm | |||
Width | N/A 11 in27.9 mm | |||
Height | N/A 17 in43.2 mm | |||
Weight | N/A 49 lb22.2 kg | |||
Test Range for Normal Model (50 cm²) | N/A 0.1 to 200 cm³/(m²·day)0.007 to 12.9 cm³/(100 in²·day) | N/A 0.1 to 100 g/(m²·day)0.006 to 6.45 g/(100 in²·day) | ||
Test Range for Masked Model (5.0 cm²) | N/A 0.1 to 2000 cm³/(m²·day)0.07 to 129.0 cm³/(100 in²·day) | N/A 1.0 to 1000 g/(m²·day)0.06 to 64.5 g/(100 in²·day) | ||
Resolution | N/A 0.001 cm³/(m²·day) | N/A 0.001 g/(m²·day) | ||
Repeatability1 | N/A 0.05 cm³/(m²·day)1 % | N/A 0.05 g/(m²·day)1 % | ||
Temperature Control Range | N/A 10 to 40 ºC | |||
Test Temperature Range Tolerance (±) | N/A 0.5 ºC | |||
Humidity Control, Film Cell, Test Gas | N/A 35 to 90 %100 % | |||
Humidity Control, Film Cell, Test Gas Tolerance (±) | N/A 3 % | |||
Film Thickness | N/A Up to 120 mil | |||
Industry Standards | N/A American Society for Testing and Materials (ASTM) E398 International Organization for Standardization (ISO) 15106-1 National Standard (Recommended) (GB/T) 30412-2013 | |||
Conformance Standards | N/A Canadian Standards Association (CSA) Safety Compliance European Conformity (CE) Underwriters Laboratories (UL) | |||
Accessories | N/A Printer | |||
Accurate Sensors |
N/A
The OX-TRAN® 1/50 uses our reliable Coulometric sensor that requires no calibration and complies with the ASTM standard D3985. The Permatran-W® 1/50 G uses our reliable RH sensor for accurate transmission rate readings that complies with the ASTM standard E398. |
|||
Efficient Use of Space | N/A The upright design and compact footprint require less lab space than many other permeation instruments. It’s completely integrated control system with display makes it a perfect standalone instrument. | |||
Applications | N/A The 1/50 Series are designed to be an effective yet simple-to-use instrument for a wide range of applications where low throughput is acceptable. The testing capability make them an ideal OTR instrument to test single samples from mono-layer to multi-layer films, coated films and coated paper board. Whether it is research and development at a university, or as a QC instrument to support production operations it provides reliable data to support your permeation testing needs. | N/A The 1/50 Series are designed to be an effective yet simple-to-use instrument for a wide range of applications where low throughput is acceptable. The testing capability make them an ideal WVTR instrument to test single samples from mono-layer to multi-layer films, coated films and coated paper board. Whether it is research and development at a university, or as a QC instrument to support production operations it provides reliable data to support your permeation testing needs. | ||
Removable Cartridge |
N/A
|
|||
Automated Control Features |
N/A
|
|||
Digital Display with Keypad Interface |
N/A
|
|||
Basic Permeation Instrument | N/A The 1/50 series Instruments are designed to be easy to use and provides reliable accurate test results. They are a cost-effective option for laboratories looking to start in-house permeation testing. | |||
Simple Operation | N/A The easy-to-read digital display has advisory prompts for inputs to step operators through the requirements to set up and run a test. Advanced users can enter individual test parameters via the key pad, then run the test and/or save it as a method or Quick Start for use by other operators. This reduces the training needed to achieve reliable and repeatable test results. Press the Quick Start button to initiate a fully automated test following stored parameters, thus reducing operator variability. Final test reports can be printed with the optional printer. The keypad is easy to learn and use while the automated testing provides consistent results and fewer potential errors. | |||
Ease of Loading | N/A These instruments feature our exclusive test cell drawer design with one horizontal removable easy-to-load test cartridge that improves test repeatability. A single button opens and closes the drawers, and the cartridge is automatically clamped in place with consistent and even force on any sample thickness. This approach provides greater test repeatability than manual or cam clamping methods. With the cartridge removed, it is easy to clean and consistently load samples on the bench-top, reducing operator variability. | |||
OX-TRAN® Coulometric Sensor |
N/A
|
N/A | ||
Permatran-W® High Sensitivity RH Sensor | N/A |
N/A
|
||
Warranty | N/A Full 100% parts and workmanship warranty for 12 months | |||
Additional Information | N/A The OX-TRAN® 1/50 has an OTR detection range from 0.1 to 200 cc/(m²·day). The upper detection limit can be extended to 2,000 cc/(m²·day) with the use of a 5 m² mask or 960 cc/(m²·day) using atmospheric oxygen in place of the normal 100% O2. | N/A The Permatran-W® 1/50 G has a WVTR detection range from 0.1 to 100 g/(m²·day). The upper detection limit can be extended to 1,000 g/(m²·day) with the use of a 5 cm² mask. | ||
|