COMPANY HEADER
Request Information
A More Powerful Way to Mix Gas!

Gas mixer for mixing 2 or 3 gasses: argon, carbon dioxide, nitrogen, oxygen and air

The revolutionary Dansensor® MAP Mix Provectus Argon uses an entirely new operating principle to advance the accuracy, operation and appearance of a gas mixer. Simple to use, highly reliable and rich in data, this mixer gives vital feedback on information such as current gas flow, total gas consumption and actual gas mix at any time.

It is also simple to configure. When ordering, you no longer need to worry about specifying the correct pressure, combination of gasses or whether it will work with your onsite generation system.
Unit of Measure

Specifications

Brands

N/A AMETEK® Dansensor® MOCON®

Mixer Configurations

N/A 2-gas or 3-gas models available, with LCD display or as "Black-Box" without display

Connections

N/A 2 x RS232C| LAN 10/100 Mbit (Modbus TCP)| USB| 24 VDC Logic for Start/Stop and Alarm

Autoranging Alternating Current (AC) Voltage

N/A 103 to 132 V207 to 264 V

Frequency

N/A 47 to 63 Hz

Height

N/A 192 mm

Width

N/A 230 mm

Depth

N/A 375 mm

Weight

N/A 12.0 to 14.0 kg

Compliances

N/A European Conformity (CE)

Gas Media

N/A Dry and clean O2, CO2, Ar, N2 or Air (0°C to +50°C / 32°F to +122°F gas temperature )

Gas Inlet Pressure

N/A 30 to 145 psi2 to 10 bar

Pressure Drop

N/A Example: 1 bar at 10 bar input pressure (14.5 psi at 145 psi input pressure)

Gas Flow per Gas String at (0.21 to 17.6 Standard Cubic Feet per Minute(SCFM))

N/A 6 to 500 L/min

Maximum Output Gas Flow (2-Gas)

N/A 1000 L/min2115 scfh

Maximum Output Gas Flow (3-Gas)

N/A 1500 L/min3175 scfh

Note for Maximum Output Gas Flow

N/A Depending on mixture setting

Mixer Setting Range

N/A 0.2 to 100 %

Mixer Accuracy

N/A ± 2% absolute in flow ranges above 50 L/min (105 SCFH) total output flow. Argon: ± 2% absolute at argon flow > 50 bar

Flow Measuring

N/A Total and daily consumption.

Operating Modes

N/A Buffer or flow configuration, selectable in software and by installation

Protection Kit

N/A Ingress Protection (IP45) National Electrical Manufacturers Association (NEMA 3S)

Bracket, Assembly

N/A Can be combined with MAP Check 3 and MAP Check Vacuum 3: 2 brackets, 8 screws.

Buffer Tank Kit

N/A Tank 15 L, fittings

Flow Range for Typical Mix1 for 2 Gases at (Ar 82% + CO2 18%)

N/A 33 to 609 L/min

Flow Range for Typical Mix1 for 3 Gases at (Ar 70% + CO220% + O210%)

N/A 60 to714 L/min

Flow Range for Typical Mix1 for 2 Gases at (Ar 90% + CO2 10%)

N/A 60 to 555 L/min

Flow Range for Typical Mix2 for 3 Gases at (Ar 70% + CO228% + O22%)

N/A 300 to 714 L/min

Flow Range for Worst Case Mix for 2 Gases at (Ar 98% + CO2 2%)

N/A 300 to 509 L/min

Flow Range for Worst Case Mix for 3 Gases at (Ar 88% + CO210% + O22%)

N/A 300 to 568 L/min

Flow Range for Best Case Mix for 2 Gases at (Ar 50% + CO2 50%)

N/A 12 to 1000 L/min

Flow Range for Best Case Mix for 3 Gases at (Ar 34% + CO233% + O233%)

N/A 18 to 1470 L/min

Benefits

Benefits

N/A
  • Uses an intuitive touch screen for easy set-up and operation
  • Meets traceability requirements by storing accurate information about current gas flow, consumption over time and gas mix
  • Avoids operator errors with programing of up to 10 standard gas mixes
  • Integrates fully with the Dansensor® MAP Check 3 gas analyzer for ultimate eff effectiveness

Features

Features

N/A
  • Data logging of consumption, date, time and gas mix
  • Very low pressure drop over the mixer, making it suitable for working with nitrogen and oxygen generators
  • USB, Ethernet (LAN), RS232, Modbus TCP connections for data logging and control
  • Mixes oxygen, nitrogen, carbon dioxide, air and argon (optional)

How Does it Work?

How Does it Work?

N/A
  1. After unpacking, use the intuitive touch screen to easily program the mixer according to the gasses connected and the desired gas mixture. The Dansensor® MAP Mix Provectus Argon can be programmed with up to 10 preset gas mixtures for easy change of gas mix by the operator.
  2. During operation the Dansensor® MAP Mix Provectus Argon ensures the correct gas mixture for the application and keeps the operator informed about inlet pressure, outlet pressure and gas flow. In case of any irregularities, the mixer alerts the operator.
  3. The Dansensor® MAP Mix Provectus Argon provides operators and quality personnel with vital information about actual gas consumption, inlet pressure, outlet pressure and gas mixture. Best of all, everything can be logged and transferred to a PC or an external data warehouse.

Additional Information

Additional Information

N/A Your only decision is whether you need to mix two or three gasses. All other specifications can be set the first time you start the gas mixer.

Even though it is only slightly larger than a shoebox, the Dansensor® MAP Mix Provectus Argon still delivers an outstanding gas mixing capacity of up to 90 m3/hour (3200 SCHF). If you require even more, you can bridge up to three mixers and triple the capacity.

Note

Note

N/A Specifications subject to change without notice.